The Vernéa Pole is located at Petit Beaulieu in the town of Clermont-Ferrand.

Back to installation list
From :
To :


Acide Chlorhydrique (HCL) mg/Nm3

Waste incineration releases hydrochloric acid (HCl). Over 98% HCl are captured by the wet FGD system. Continuous measurement allows the hydrochloric acid to monitor the effectiveness of treatment of smoke.

The daily average of adjusted measures should not exceed 10mg / Nm3.mg / Nm3

Monoxyde de Carbone (CO) mg/Nm3

Formation (CO) is the result of incomplete combustion. Continuous measurement of carbon monoxide makes it possible to measure the effectiveness of incineration.

The daily average of adjusted measures should not exceed 50 mg/Nm3.

Dioxyde de Soufre (SO2) mg/Nm3

L’incinération des déchets libère des oxydes de Soufre (SO2). Ce gaz est capté par un traitement humide des fumées. Le dioxyde de Soufre est mesuré en continu.

L’incinération des déchets libère des oxydes de Soufre (SO2). Ce gaz est capté par un traitement humide des fumées. Le dioxyde de Soufre est mesuré en continu.

Dioxyde d'Azote (NOx) mg/Nm3

Toute combustion génère des oxydes d'azote (NOx). La mesure continue des NOx permet de contrôler l'efficacité de l'incinération.

La moyenne journalière des mesures corrigées ne doit pas excéder 80 mg/Nm3.

Poussière (10) (POUS_10) mg/Nm3

Toute combustion libère des particules et des cendres qui sont piégées dans les filtres à manches de l’usine. Plus de 98 % des poussières sont captées par le traitement de fumées de l'usine. La mesure continue des poussières permet de contrôler l’efficaci

.La moyenne journalière des mesures corrigées ne doit pas excéder 10mg/Nm3.

Ammoniac (NH3) mg/Nm3

Processing residues NOx present in the exhaust smoke oven is provided by a catalyst in which water is injected ammoniacale.Un significant release of NH3 is the consequence of an imbalance in the operation of the catalyst before it has a impact on NOx emis

The daily average of adjusted measures should not exceed 30mg / Nm3.

Carbone Organique Total (COT) mg/Nm3

A significant release organic carbon is the result of incomplete combustion. His show is not harmful to the environment but is a sign of incomplete treatment of waste. Continuous measurement of CO can measure the efficiency of incineration.

The daily average of adjusted measures should not exceed 10mg / Nm3.

Acide Fluorhydrique (HF) mg/Nm3

Waste incineration releases of acid gases which are purified by dry processing system of the plant fumes or milk of lime in the washers. Over 95% of HF is sensed following the sodium bicarbonate injection. Continuous measurement of the hydrochloric acid a

The daily average of adjusted measures should not exceed 1mg / Nm3.